Washbasin · Laminar M22/M24
RCM Basic Hospital
6 variants · part no. 4131106–4136508
RCM Basic Hospital aerators have a very good resistance to calcification.
Thread / size
Flow rate
Part no.:—
Stream Characteristics
Laminar stream
A clear, closed water stream without admixed air — preferred in clinical and hygiene applications.
A clear, closed water stream without admixed air — preferred in clinical and hygiene applications.
Application Areas
Drinking water only
Basin faucet
Kitchen faucet
Not suitable for pressureless water heaters
Technical Characteristics
| Plastics | POM |
| Elastomers | EPDM |
| Metals | Brass |
| Temperature | 60°C/140°F max. continuous, 70°C/158°F short-term |
| Supply line pressure | Max. 6 bar/87 psi continuous, max. 8.5 bar/123 psi ≤ 3 min.; avoid water hammer |
| Standards | Meets requirements of EN246 and ASME A112.18.1 |
| Drinking water | Materials meet all relevant international drinking water certifications |
AttentionProduct may not be altered! Shall not be used for hot water application exceeding 70°C
AttentionMax. mounting torque 1.5 Nm steadily applied
Please refer to the datasheet „Housing Overview STD Size“.
DisclaimerR.C. Mannesmann aerators are designed exclusively for the use with drinking water. For use in non-drinking water applications, tests must be carried out and confirmed by the customer himself.
Dimensions (in mm) — according to EN246

Source: datasheet — illustration only.
Questions about this product, or interested in a quotation?
Get in touchAll variants — part numbers
| Part no. | Description | Thread / size | Flow rate |
| 4131106 | RCM basic LP M22 HOS CFR 6L | M22x1 | 6 L/min |
| 4131108 | RCM basic LP M22 HOS CFR 8L | M22x1 | 8 L/min |
| 4132106 | RCM basic LP M24 HOS CFR 6L | M24x1 | 6 L/min |
| 4132108 | RCM basic LP M24 HOS CFR 8L | M24x1 | 8 L/min |
| 4136506 | RCM basic LP 22/24 HOS CFR 6L | STD | 6 L/min |